DPS DEJO PRESS GRID STEPS

Dejo pressed-grid steps (DPS) can be made entirely to measure, but in most cases standard sizes available from stock are used. Each step is fitted as standard with two gusset plates with hole pattern for fastening and an anti-slip profile at the front. In addition, the bearing and/or filling bars can also be provided with anti-slip serrations.

A popular type of stair step is the DPS with bearing bar 30-2, filler bar 10-2 and meshes 34x33 in width 800 and depth 240mm. This type is suitable for both light and heavy passenger traffic. For heavy persons, we take into account a sturdy man/woman carrying 2 heavy toolboxes.



Projects Contact      Order



Dimensions of steel mesh steps:
For steps in hot-galvanised version, the following applies as a guide to the minimum and maximum dimensions:

Bearing bar length : 140 - 3000 mm
Bearing bar height : 25 - 150 mm
Bearing bar width : 2 - 5 mm
 
Filling bar length : 100 - 500 mm
Filling bar height : 20 - 50 mm
Filling bar width : 2 - 5 mm
 
Finishing:
  • Hot-dip galvanised in accordance with NEN-EN-ISO 1461
  • Powder coating using TVP Duplex process









Most steps can be fitted with anti-slip, double anti-slip and kick or lowered edge. From standard shapes to special cut-outs

Stainless steel 304 - 316 press gratings:
For gratings made of stainless steel, the following applies as a guide to minimum and maximum dimensionse:

Bearing bar length : 140 - 1400 mm
Bearing bar height : 20 - 50 mm
Bearing bar
width
: 2 - 5 mm
     
Filling bar length : 140 - 3000 mm
 
Bearing bar height
: 10 - 50 mm
Filling bar
width
: 2 - 5 mm
 
Finishing:
  • Pickled and passivated
  • Powder coating using TVP Duplex process










Most steps can be fitted with anti-slip, double anti-slip and kick or lowered edge. From standard shapes to special cut-outs.

The various meshes

dejo offers the possibility to produce the gratings in different mesh sizes. Usually, press gratings steps are produced as standard in mesh size 34.33 x 33.33 mm. But dejo can produce gratings in many different meshes: e.g. 33 x 11 mm, 22x11 mm and 22x33 mm etc.

The mesh table below shows the various possibilities.



MESH TABLE

 

Bearing bar distance 

Filling bar distance h.o.h

 

1111

2222

3333

4444

5000

6666

7777

8888

9999

1666

2222

3433

4444

6666

 


standard mesh size 3433 x 3333




Side panels for press-grate steps
Dejo's standard dimensions for the side panels are the lower dimensions in accordance with the DIN standard. On request, other sketch plates with different pitch can be supplied.

DPS grating side panels:

DPS persrooster k
Dimensions side panels according DIN
    A = 200 A = 240 A = 270 A = 305
    B = 35 B = 35 B = 35 B = 35
    C = 100 C = 120 C = 150 C = 180
    D = 55 D = 55 D = 55 D = 55
    E = 15 E = 15  E = 15 E = 15
           

 


Standard stock
Dejo has a wide range of standard gratings, grating steps, dejogrip steps, plastic gratings and clips suitable for walking loads and light traffic. More than 300 articles are delivered from stock from our warehouse in Wolvega. Ordered before 11:00, delivered within one week. 

Grid specifications
Bearing bars see table, filler bars 10 x 2 mm. 
Mesh size of bearing and cross bars 34.33 x 33.33 mm centres. 
A tolerance on length and width of + 0 to - 4 mm applies to the grid dimensions. 
The first dimension (length) indicates the length of the bearing bars (span).

Here you can also directly order online

ORDER


mesh size 34,33 x 33,33 mm h.o.h., side panels according DIN
Bearing bar:  Lengte: A = 200 mm A = 240 mm A = 270 mm A = 305 mm
25 x 2 mm: 500      
  600    
  700    
30 x 2 mm 800  
  900  
  1000  
30 x 3 mm 800  
  900  
  1000  
40 x 3 mm 1200  

 

constructierichtlijnen voor trap met roostertredenConstruction guidelines for stairs

  • The standard step lengths are 500, 600, 700, 800, 900 and 1000 mm.
    A staircase with more than 4 steps should be fitted with handrails. 
    For more than 18 steps, a landing should also be used. 
    The landing length must be at least 1 metre. 
    For stair widths exceeding 1 metre, the landing length is equal to the stair width. 
    For comfortable walkability, Dejo's rule of thumb is: going forward + (2 x going up) = 630 mm. 
    The overlap should be at least 10 mm. 
    The stair pitch can be determined using the ratio between height and base length: L : H = D. 
    The desired stair pitch is between 30° and 45°.


From the table below, choose the closest proportion:

RELATIONS
Staircase ramp: 60º 57º 55º 52º 50º 47º 45º 42º 40º 37º 35º 32º 30º
Usable steps: 240 235 225 220 220 215 210 205 200 190 185 175 170
Usable steps: 150 160 170 180 190 200 210 220 230 250 260 280 290
Usable step width: 160 170 200 200 200 230 230 260 260 260 300 300 300
Base length-to-height proportion 0,58 0,65 0,70 0,78 0,84 0,93 1,00 1,11 1,19 1,33 1,43 1,60 1,73


If the stair slope is not known, but the height (H) and the base length (L) are, then divide the base length (L) by the height(H).

constructierichtlijnen voor trap met bordesVoorbeeld 

Staircase ramp (D) : ?
Basic length (L) : 3,0 m
Height (H) : 2,5 m
L : H = 3,0 : 2,5 = 1,2
The staircase ramp is 40°






Download more technical information on the DPS Dejo press grid steps here:

[downloads]